Mitel 6867i Administrator's Manual page 677

6800 series
Hide thumbs Also See for 6867i:
Table of Contents

Advertisement

To set blog modules:
7. Select the applicable module.
8. Enter a debug level value in the "Debug Level" field for a module. Valid values are:
DEBUG LEVEL
Fatal Errors
Errors
Warnings
Init
Functions
Info
All debug levels OFF
All Debug Levels ON
The value of "0" turns all debug levels OFF for a module. The value of "65535" turns all
debug levels ON for a module.
To turn two or more debug levels on at the same time, you add the value associated with
each level. For example, Fatal Errors + Errors + Warnings = 1 + 2 + 4 = 7
log module linemgr: 7
log module user interface: 7
log module sip: 7
In the above example, fatal errors, general errors, and warnings are logged for the line
manager, user interface, and SIP call control modules.
9. Click Save Settings to save your settings.
10. Click on Operation->Reset.
11. In the "Restart Phone" field click Restart to restart the IP phone.
To perform support tasks:
12. To store the local configuration file to the specified location, click on Save As in the "Get
local.cfg" field.
13. To store the server configuration file to the specified location, click on Save As in the "Get
server.cfg" field.
14. To display task and stack status information, as well as Free Memory and Maximum Block
Free Memory on the phone, click on Show in the "Show Task and Stack Status" field.
Note: The local and server configuration file information and the task and stack
status information is for use by Mitel Technical Support for troubleshooting purposes.
Reference
For information that describes solutions to most common problems using the IP phones, see
the next section,
"Troubleshooting Solutions"
VALUE
1 (default)
2
4
8
16
32
0
65535
on