PARAMETER –
ethernet port 0
DESCRIPTION
FORMAT
DEFAULT VALUE
RANGE
EXAMPLE
PARAMETER –
ethernet port 1
DESCRIPTION
FORMAT
DEFAULT VALUE
RANGE
EXAMPLE
Operational, Basic, and Advanced Parameters
CONFIGURATION FILES
startup.cfg, <model>.cfg, <mac>.cfg
The send (TX) and receive (RX) method to use on Ethernet port 0 to
transmit and receive data over the LAN.
Integer
0
0 - Auto Negotiate
1 - Full Duplex, 10Mbps
2 - Full Duplex, 100Mbps
3 - Full Duplex, 1000Mbps (applicable for the 6865i, 6867i, 6869i,
and 6873i IP phones only)
4 - Half Duplex, 10Mbps
5 - Half Duplex, 100Mbps
6 - Half Duplex, 1000Mbps (applicable for the 6865i, 6867i, 6869i,
and 6873i IP phones only)
ethernet port 0: 4
CONFIGURATION FILES
startup.cfg, <model>.cfg, <mac>.cfg
The send (TX) and receive (RX) method to use on Ethernet port 1 to
transmit and receive data over the LAN.
Integer
0
0 - Auto Negotiate
1 - Full Duplex, 10Mbps
2 - Full Duplex, 100Mbps
3 - Full Duplex, 1000Mbps (applicable for 6865i, 6867i, 6869i, and
6873i IP phones only)
4 - Half Duplex, 10Mbps
5 - Half Duplex, 100Mbps
6 - Half Duplex, 1000Mbps (applicable for the 6865i, 6867i, 6869i,
and 6873i IP phones only)
ethernet port 1: 2