SETTING VALUES FOR THE MODULE/DEBUG LEVELS
There are 6 debug levels for the modules. Each debug level has a value you can use to turn
individual levels ON and OFF. The following table identifies these debug levels and their values.
The value of "1" (fatal errors) is the default setting for all modules.
DEBUG LEVEL
Fatal Errors
Errors
Warnings
Init
Functions
Info
All debug levels OFF
All Debug Levels ON
Example 1
To turn two or more debug levels on at the same time, you add the value associated with each
level. For example,
Fatal Errors + Errors + Warnings = 1 + 2 + 4 = 7
log module linemgr: 7
log module user interface: 7
log module sip: 7
In the above example, fatal errors, general errors, and warnings are logged for the line manager,
user interface, and SIP call control modules.
Example 2
Functions and Info = 16 + 32 = 48
log module dis: 48
log module net: 48
log module snd: 48
In the above example, functions and general information are logged for the display drivers,
network, and sound modules.
Example 3
log module rtpt: 0
log module ind: 65535
In the above example, all debug levels are OFF for the Real Time Transport module. All debug
levels are ON for the indicator module.
You can set the Module/Debug Levels using the configuration files or the Mitel Web UI.
VALUE
1 (default)
2
4
8
16
32
0
65535