Recirculation Control Motor Test
1. Disconnect the 5P connector from the recirculation
control motor.
NOTIEEI
Incorrectly applying power and ground to
the recirculation control motor will damage it.
Follow the instructions carefully.
2. Connect batterv Dower to the No. 5 terminal ofthe
recirculation control motor, and ground the No. 1
and No. 2 terminals; the recirculation control motor
should run smoothly. To avoid damaging the
recirculation control motor, do not reverse power
and ground. Disconnect the No. 1 or No. 2
terminals from ground; the recirculation control
motor should stop at Fresh or Recirculate. Don't
cycle the recirculation control motor for a long time.
RECIRCULATION
CONTROL MOTOR
lf the recirculation control motor does not run in
step 2, remove it, then check the recirculation
control linkage and doors for smooth movement.
. lf the linkage and doors move smoothly, replace
the recirculation control motor.
. lfthe linkage or doors stick or bind, repairthem
as needed.
Recirculation Control Motor
Replacement
1. Open the glove box. Remove the glove box stop on
each side, then hang the glove box down (see page
zu-oat.
2. Disconnect the 5P connector (A) from the
recirculation control motor {B}. Remove the self-
tapping screws and the recirculation control motor
from the blower unit.
t_____----
lnstall the motor in the reverse order of removal.
Make sure the pin on the motor is properly
engaged with the linkage. After installation, make
sure the motor runs smoothlv.