Result
The automatic negotiation of connection parameters on an interface is deactivated.
Further notes
You enable the autonegotiation of connection parameters with the
2.1.10.9

mtu

Description
With this command, you configure the size of the Maximum Transmission Unit (MTU) for an
interface.
Requirement
● The Interface must be shut down.
You are in the Interface configuration mode.
The command prompt is as follows:
cli(config-if-$$$)#
Syntax
Call up the command with the following parameters:
mtu <frame-size(64-1500)>
The parameter has the following meaning:
Parameter
frame-size
At system start or when using the
following defaults apply:
● The size of the MTU is configured to 1536 bytes.
Result
The setting for the size of the MTU is configured.
Further notes
You can shut down the interface with the
You display this setting with the
You display this setting and other information with the
SCALANCE S615 Command Line Interface
Configuration Manual, 06/2015, C79000-G8976-C406-02
Description
Size of the MTU in bytes
command with the option
restart
shutdown complete
show interface mtu
negotiation
Range of values
64 ... 1500
or
memory
command.
command.
command.
show interfaces
Configuration
2.1 System
command.
, the
factory