Clear Line Vty - Siemens SCALANCE S615 Configuration Manual

Simatic net industrial ethernet security command line interface
Hide thumbs Also See for SCALANCE S615:
Table of Contents

Advertisement

Further notes
You exit the Global configuration mode with the
2.1.4

clear line vty

Description
With this command, you close a console session on the device.
With the
Requirement
You are in the Privileged EXEC mode.
The command prompt is as follows:
cli#
Syntax
Call up the command with the following parameters:
clear line vty {<line-number(2-9)>|all}[forceful-clear]
The parameters have the following meaning:
Parameter
line-number
all
forceful-clear
Result
The console session is closed.
Further notes
You show the logged-on users with the
SCALANCE S615 Command Line Interface
Configuration Manual, 06/2015, C79000-G8976-C406-02
option, you close a session and that is not reacting.
forceful-clear
Description
Number of the connection that will be
terminated
terminates all connections
closes a session that is not reacting
command.
end
Range of values / note
2 ... 9
-
-
command.
show users
Configuration
2.1 System
47