5.1.3.7

switchport pvid

Description
With this command, you assign an interface to a VLAN and configure the port VLAN
identifier (PVID) for it. If a received frame has no VLAN tag, it has a tag added with the VLAN
ID specified here and is sent according to the switch rules for the port.
Requirement
You are in the Interface configuration mode.
The command prompt is as follows:
cli(config-if-$$$)#
Syntax
Call up the command with the following parameters:
switchport pvid <vlan-id(1-4094)>
The parameter has the following meaning:
Parameter
vlan-id
Result
The PVID is configured
Further notes
You can reset the setting to the default with the
You configure the VLAN ID with the
You display the setting and other information with the
SCALANCE S615 Command Line Interface
Configuration Manual, 06/2015, C79000-G8976-C406-02
Description
Number of the addressed VLAN
switchport access vlan
Range of values / note
1 ... 4094
command.
no switchport pvid
command.
show vlan port config
Network structures
5.1 VLAN
command.