No Service - Siemens SCALANCE S615 Configuration Manual

Simatic net industrial ethernet security command line interface
Hide thumbs Also See for SCALANCE S615:
Table of Contents

Advertisement

Parameter
range
number
number
Result
The service is configured.
Further notes
You delete this service with the
You display the service with the
9.2.4.38

no service

Description
With this command, you delete all services or a specific service.
Requirement
● The corresponding service has been created and is not being used anywhere.
● You are in the FIREWALL configuration mode.
The command prompt is as follows:
cli(config-fw)#
Syntax
Call up the command with the following parameters:
no service {name <string(32)> | all}
The parameters have the following meaning:
Parameter
name
string
all
SCALANCE S615 Command Line Interface
Configuration Manual, 06/2015, C79000-G8976-C406-02
Description
Keyword for a port range
Start port
End port
command.
no service
show firewall ip-services
Description
Keyword for service name
Service name
Deletes all service names
Security and authentication
Range of values / note
-
0 ... 65535
Specify the start port and end port, e.g.
10 - 20
command.
Range of values / note
-
Specify a valid service name.
Maximum of 32 characters
-