The parameters have the following meaning:
Parameter
all
manual
learned
Result
The device uses the specified DNS servers.
Further notes
You display this setting and other information with the
command.
You create a manually configured DNS server with the
6.5.3.4

shutdown

Description
With this command, you end the DNS client.
Requirement
You are in the DNS CLIENT configuration mode.
The command prompt is as follows:
cli(config-dnsclient)#
Syntax
Call the command without parameter assignment:
shutdown
Result
The DNS client is ended.
Further notes
You start the DNS client with the
SCALANCE S615 Command Line Interface
Configuration Manual, 06/2015, C79000-G8976-C406-02
Description
The device uses all available DNS
servers.
The device uses only the manually
configured DNS servers.
The device uses the DNS servers that
are transferred automatically.
command.
no shutdown
Network protocols
Range of values / note
Default
-
-
show dnsclient information
command.