Diagnostics
10.1 Event and fault handling
Parameter
email
all
Result
The client selected for the transfer is disabled.
Further notes
You display the status of the events and the clients with the
You enable the function with the
10.1.10.4

event config

Description
With this command, you configure which of the various message types of the device will be
stored or forwarded.
The following events or message types are available:
● Message if there is cold or warm restart
● Message when there is a status change on a physical interface
● Message if there is an incorrect login
● Message when there is a status change in the power supply
● Message when there is a status change in the error monitoring
● Message when using VPN
● Message when using firewall rules
● Message when changing the connection status
● Message on connection establishment and when the configuration changes
● Message when there is a status change of the digital input.
These messages can be processed by the clients in different ways:
● Entry in the logbook of the device
● Sending the message to the Syslog server of the system
● Sending an e-mail
● Sending an SNMP trap
● Lighting up of the error LED
● Switching at the digital output
426
Description
Disables the client that sends the e-mails
Disables all clients at once
client config
show events config
command.
SCALANCE S615 Command Line Interface
Configuration Manual, 06/2015, C79000-G8976-C406-02