You configure the remote subnet with the
You display this setting and other information with the
9.3.4.3

conn-mode

Description
With this command, you specify the role the remote stations will adopt.
Requirement
You are in the IPSEC REMOTE END configuration mode.
The command prompt is as follows:
cli(config-ipsec-rmend-X)#
Syntax
Call up the command with the following parameters:
conn-mode <roadwarrior|standard>
The parameters have the following meaning:
Parameter
roadwarrior
standard
Result
The role is configured.
Further notes
You display this setting and other information with the
9.3.4.4

subnet

Description
With this command, you configure the remote subnet of the VPN remote station.
SCALANCE S615 Command Line Interface
Configuration Manual, 06/2015, C79000-G8976-C406-02
Description
Roadwarrior mode
The device accepts VPN connections from remote sta-
tions with an unknown address.
Standard mode
The device establishes a connection to or from a known
remote station. The remote station is identified by the IPv4
address or the DDNS hostname.
command.
subnet
show ipsec remoteend
show ipsec remoteend
Security and authentication
9.3 IPsec VPN
command.
Range of values / note
-
-