3.3.2

show digital output

Description
This command shows the current setting of the digital output.
Requirement
You are in the User EXEC mode or in the Privileged EXEC mode.
The command prompt is as follows:
cli>
Syntax
Call the command without parameters:
show digital output
Result
The current setting of the digital output is displayed.
3.3.3

Commands in the global configuration mode

This section describes commands that you can call up in the Global configuration mode.
In Privileged EXEC mode, enter the
Commands relating to other topics that can be called in the Global configuration mode can
be found in the relevant sections.
You exit the Global configuration mode with the
Privileged EXEC mode again.
3.3.3.1

digital output close

Description
This command closes the digital output.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
SCALANCE S615 Command Line Interface
Configuration Manual, 06/2015, C79000-G8976-C406-02
or
cli#
command to change to this mode.
configure terminal
or
end
exit
Functions specific to SCALANCE
3.3 Digital input/output
command and are then in the