Ipv4Rule Set To - Siemens SCALANCE S615 Configuration Manual

Simatic net industrial ethernet security command line interface
Hide thumbs Also See for SCALANCE S615:
Table of Contents

Advertisement

Security and authentication
9.2 Firewall
Syntax
Call up the command with the following parameters:
ipv4rule idx <number(1-100)> set srcip <ip_addr>
The parameters have the following meaning:
Parameter
idx
number
srcip
string
Result
The source of the corresponding IPv4 firewall rule has been changed.
Further notes
You display this setting and other information with the
command.
You obtain the numbers with the
9.2.4.18

ipv4rule set to

Description
With this command, you change the incoming direction (to).
Requirement
● The IPv4 firewall rule has been created.
● You are in the FIREWALL configuration mode.
The command prompt is as follows:
cli(config-fw)#
Syntax
Call up the command with the following parameters:
330
Description
Keyword for index
Number corresponding to a spe-
cific IPv4 rule.
Keyword for the source
Address that sends IPv4 packets. •
ipv4rule show-rules
Range of values / note
-
Enter the required number.
1 ... 100
Individual IP address: Specify the IP
address.
IP range: Specify the range with the
start address "-" end address,
e.g.192.168.100.10 - 192.168.100.20.
All IP addresses: Specify " 0.0.0.0/0".
show firewall ip-rules ipv4
command.
SCALANCE S615 Command Line Interface
Configuration Manual, 06/2015, C79000-G8976-C406-02

Hide quick links:

Advertisement

Table of Contents
loading