Diagnostics
10.1 Event and fault handling
10.1.10.1

add log

Description
With this command, you create an entry in the log.
Requirement
You are in the EVENTS Configuration mode.
The command prompt is as follows:
cli(config-events)#
Syntax
Call the command without parameters:
add log <log entry>
The parameter has the following meaning:
Parameter
log entry
Result
The entry has been made in the logbook.
10.1.10.2

client config

Description
With this command, you enable one of the clients that processes or forwards the messages
of the device.
The following clients are available:
syslog
trap
email
Requirement
You are in the EVENTS Configuration mode.
The command prompt is as follows:
cli(config-events)#
424
Description
Entry in the logbook
: sends the messages to the Syslog server
: sends the messages as SNMP trap to a configured recipient
: sends the messages as e-mail
Range of values / note
max. 150 characters
SCALANCE S615 Command Line Interface
Configuration Manual, 06/2015, C79000-G8976-C406-02