Related Information
"Reconnect Power and Data Cables" on page 233
■
Reconnect Power and Data Cables
1.
Reconnect the data cables to the rear of the server, as appropriate.
If the cable management arm (CMA) is in the way, extend the server approximately 13 cm (5
inches) out of the front of the rack.
2.
Reconnect the power cables to the power supplies.
If necessary, reinstall the cables into the cable management arm and secure
3.
them with Velcro straps.
4.
Power on the server.
See
"Power On the Server" on page
Related Information
"Disconnect Cables From the Server" on page 60
■
"Reinstall the Server in the Rack" on page 230
■
"Return the Server to the Normal Rack Position" on page 231
■
"Power On the Server" on page 233
■
Power On the Server
As soon as the power cords are connected, standby power is applied. In standby power mode,
the Power/OK LED on the server front panel blinks steadily. Depending on the configuration of
the firmware, the system might boot. If it does not boot, follow this procedure.
Power on the server by performing one of the following actions:
Press the Power button on the front bezel.
■
Log in to the Oracle ILOM web interface, click Host Management → Power Control and
■
select Power On from the Select Action list.
Log in to the Oracle ILOM command-line interface (CLI), and type the following command
■
at the Oracle ILOM prompt:
start /System
->
233.
Returning the Server to Operation
Reconnect Power and Data Cables
233
Need help?
Do you have a question about the X5-2L and is the answer not in the manual?