Messages and Descriptions
SNMP Trap: sunHwTrapPowerSupplyError
Oracle ILOM Event Message: PS_INPUT_RANGE_ERROR DEASSERT
Severity and Description: Major; A power supply sensor has detected an error.
SNMP Trap: sunHwTrapPowerSupplyError
Oracle ILOM Event Message: PS_CONFIG_ERROR ASSERT
Severity and DescriptionMajor; A power supply sensor has detected an error.
SNMP Trap: sunHwTrapPowerSupplyError
Oracle ILOM Event Message: PS_CONFIG_ERROR DEASSERT
Severity and Description: Major; A power supply sensor has detected an error.
SNMP Trap: sunHwTrapSensorNonCritThresholdExceeded
Oracle ILOM Event Message: Upper noncritical threshold exceeded
Severity and Description: Minor; A sensor has reported that its value has gone above an upper
non critical threshold setting or below a lower non critical threshold setting. This generic 'sensor'
trap is generated when the SNMP agent does not recognize the component type.
The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower
threshold.
SNMP Trap: sunHwTrapSensorThresholdOk
Oracle ILOM Event Message:Upper noncritical threshold no longer exceeded
Severity and Description: Informational; A sensor has reported that its value is in the normal
operating range. This generic 'sensor' trap is generated when the SNMP agent does not recognize
the component type.
SNMP Trap: sunHwTrapSensorNonCritThresholdExceeded
Oracle ILOM Event Message: Upper noncritical threshold exceeded
Severity and Description: Minor; A sensor has reported that its value has gone above an upper
non critical threshold setting or below a lower non critical threshold setting. This generic 'sensor'
trap is generated when the SNMP agent does not recognize the component type.
The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower.
SNMP Trap: sunHwTrapSensorThresholdOk
Oracle ILOM Event Message: Upper noncritical threshold no longer exceeded
Severity and Description: Informational; A sensor has reported that its value is in the normal
operating range. This generic 'sensor' trap is generated when the SNMP agent does not recognize
the component type.
SNMP Trap: sunHwTrapSensorFatalThresholdExceeded
Oracle ILOM Event Message: Lower fatal threshold exceeded
Severity and Description: Critical; A power supply sensor has reported that its value has gone
above an upper fatal threshold setting or below a lower fatal threshold setting.
Component Name
/SYS/PS[0-1]/STATE
/SYS/PS[0-1]/STATE
/SYS/PS[0-1]/STATE
/SYS/VPS
/SYS/VPS
/SYS/VPS_FANS
/SYS/PS[0-1]/P_IN
/SYS/PS[0-1]/P_OUT
/SYS/VPS_FANS
/SYS/PS[0-1]/P_IN
/SYS/PS[0-1]/P_OUT
/SYS/PS[0-1]/P_IN
/SYS/PS[0-1]/P_OUT
Monitoring Components and Identifying SNMP Messages
Power Events