The procedures that you perform at this point depend on how your data is configured. You
might need to partition the drive, create file systems, load data from backups, or have the drive
updated from a RAID configuration.
Related Information
"Rear Panel Components and Cable Connections" on page 18
■
"Storage and Boot Drive Indicators" on page 32
■
"Install an HDD or SSD Storage Drive" on page 78
■
Servicing Fan Modules (CRU)
The fan modules are located in the front of the server. See the following procedures:
"Remove a Fan Module" on page 89
■
"Install a Fan Module" on page 92
■
Related Information
"Remove the Server Top Cover" on page 64
■
Remove a Fan Module
You do not have to power off the server to service fan modules.
You should not begin this procedure unless you have a replacement fan module and you are
ready to install it right away.
1.
Extend the server to the maintenance position.
See
"Extend the Server to the Maintenance Position" on page
To access the fan modules, open the top cover fan assembly door.
2.
Caution -
airflow to properly cool the server. Leaving the door open for more than 60 seconds, while the
server is running, might cause the server to automatically shut down.
3.
Identify the faulty fan module.
Close the top cover fan assembly door within 60 seconds to maintain adequate
61.
Servicing CRUs That Do Not Require Server Power-Off
Servicing Fan Modules (CRU)
89
Need help?
Do you have a question about the X5-2L and is the answer not in the manual?
Questions and answers