Messages and Descriptions
Oracle ILOM Event Message: event fault.memory.intel.dimm.disable-quadrank "Memory
channel is populated with too many quad-rank memory DIMMs."
Severity and Description: Informational; A memory component fault has been cleared.
SNMP Trap: sunHwTrapMemoryFault
Oracle ILOM Event Message: event fault.memory.intel.dimm.population-invalid "Memory
DIMM is improperly populated or is a type that is not compatible with other DIMMs installed."
Severity and Description: Major; A memory component is suspected of causing a fault.
SNMP Trap: sunHwTrapMemoryFaultCleared
Oracle ILOM Event Message: event fault.memory.intel.dimm.population-invalid "Memory
DIMM is improperly populated or is a type that is not compatible with other DIMMs installed."
Severity and Description: Informational; A memory component fault has been cleared.
SNMP Trap: sunHwTrapMemoryFault
Oracle ILOM Event Message: event fault.memory.intel.dimm.out-of-order "The memory
DIMMs in a channel are not populated in sequential order."
Severity and Description: Major; A memory component is suspected of causing a fault.
SNMP Trap: sunHwTrapMemoryFaultCleared
Oracle ILOM Event Message: event fault.memory.intel.dimm.out-of-order "The memory
DIMMs in a channel are not populated in sequential order."
Severity and Description: Informational; A memory component fault has been cleared.
SNMP Trap: sunHwTrapMemoryFault
Oracle ILOM Event Message: event fault.memory.intel.dimm.category-unknown "Memory
DIMM is of an unknown type or category."
Severity and Description: Major; A memory component is suspected of causing a fault.
SNMP Trap: sunHwTrapMemoryFaultCleared
Oracle ILOM Event Message: event fault.memory.intel.dimm.category-unknown "Memory
DIMM is of an unknown type or category."
Severity and Description: Informational; A memory component fault has been cleared.
Related Information
"System Chassis Components" on page 295
■
"Cooling Unit Components" on page 296
■
"Disk Backplane Components" on page 297
■
"Memory Device Components" on page 298
■
"Power Unit Components" on page 299
■
"Processor Components" on page 300
■
"System Board Components" on page 301
■
"Hard Disk Drive Components" on page 303
■
Component Name
/SYS/MB/P[0-x]/D[0-11]
/SYS/MB/P[0-x]/D[0-11]
/SYS/MB/P[0-x]/D[0-11]
/SYS/MB/P[0-x]/D[0-11]
/SYS/MB/P[0-x]/D[0-11]
/SYS/MB/P[0-x]/D[0-11]
Monitoring Components and Identifying SNMP Messages
Memory Events