Oracle X5-2L Service Manual page 317

Table of Contents

Advertisement

Messages and Descriptions
Oracle ILOM Event Message: event fault.memory.intel.dimm.disable-quadrank "Memory
channel is populated with too many quad-rank memory DIMMs."
Severity and Description: Informational; A memory component fault has been cleared.
SNMP Trap: sunHwTrapMemoryFault
Oracle ILOM Event Message: event fault.memory.intel.dimm.population-invalid "Memory
DIMM is improperly populated or is a type that is not compatible with other DIMMs installed."
Severity and Description: Major; A memory component is suspected of causing a fault.
SNMP Trap: sunHwTrapMemoryFaultCleared
Oracle ILOM Event Message: event fault.memory.intel.dimm.population-invalid "Memory
DIMM is improperly populated or is a type that is not compatible with other DIMMs installed."
Severity and Description: Informational; A memory component fault has been cleared.
SNMP Trap: sunHwTrapMemoryFault
Oracle ILOM Event Message: event fault.memory.intel.dimm.out-of-order "The memory
DIMMs in a channel are not populated in sequential order."
Severity and Description: Major; A memory component is suspected of causing a fault.
SNMP Trap: sunHwTrapMemoryFaultCleared
Oracle ILOM Event Message: event fault.memory.intel.dimm.out-of-order "The memory
DIMMs in a channel are not populated in sequential order."
Severity and Description: Informational; A memory component fault has been cleared.
SNMP Trap: sunHwTrapMemoryFault
Oracle ILOM Event Message: event fault.memory.intel.dimm.category-unknown "Memory
DIMM is of an unknown type or category."
Severity and Description: Major; A memory component is suspected of causing a fault.
SNMP Trap: sunHwTrapMemoryFaultCleared
Oracle ILOM Event Message: event fault.memory.intel.dimm.category-unknown "Memory
DIMM is of an unknown type or category."
Severity and Description: Informational; A memory component fault has been cleared.
Related Information
"System Chassis Components" on page 295
"Cooling Unit Components" on page 296
"Disk Backplane Components" on page 297
"Memory Device Components" on page 298
"Power Unit Components" on page 299
"Processor Components" on page 300
"System Board Components" on page 301
"Hard Disk Drive Components" on page 303
Component Name
/SYS/MB/P[0-x]/D[0-11]
/SYS/MB/P[0-x]/D[0-11]
/SYS/MB/P[0-x]/D[0-11]
/SYS/MB/P[0-x]/D[0-11]
/SYS/MB/P[0-x]/D[0-11]
/SYS/MB/P[0-x]/D[0-11]
Monitoring Components and Identifying SNMP Messages
Memory Events
317

Advertisement