Reconnect Power And Data Cables; Power On The Server - Oracle Exadata X5-2 Service Manual

High capacity storage server
Hide thumbs Also See for Exadata X5-2:
Table of Contents

Advertisement

For detailed information on connecting cables to the rear of the server, refer to
Connections and Ports" in Oracle Exadata Storage Server X5-2 High Capacity Installation
Guide.
Related Information
"Reconnect Power and Data Cables" on page 167

Reconnect Power and Data Cables

Reconnect the data cables to the rear of the server, as appropriate.
1.
If the cable management arm (CMA) is in the way, extend the server approximately 13 cm (5
inches) out of the front of the rack.
Reconnect the power cables to the power supplies.
2.
3.
If necessary, reinstall the cables into the cable management arm and secure
them with Velcro straps.

Power on the server.

4.
See
"Power On the Server" on page
Related Information
"Disconnect Cables From the Server" on page 54
"Reinstall the Server in the Rack" on page 164
"Return the Server to the Normal Rack Position" on page 165
"Power On the Server" on page 167
Power On the Server
As soon as the power cords are connected, standby power is applied. In standby power mode,
the Power/OK LED on the server front panel blinks steadily. Depending on the configuration of
the firmware, the system might boot. If it does not boot, follow this procedure.
Power on the server by performing one of the following actions:
Press the Power button on the front bezel.
167.
Returning the Server to Operation
Reconnect Power and Data Cables
"Rear Cable
167