Oracle X5-2L Service Manual page 157

Table of Contents

Advertisement

Cable part number 7086654 is required to connect power to the storage drive backplane.
Note -
b.   
Reconnect the auxiliary signal cable to the storage drive backplane [4].
Cable part number 7079291 is required to connect the auxiliary signal to the storage
Note -
drive backplane.
c.   
Reconnect the SAS cable to the storage drive backplane from the rear-
mounted storage drives, and the two SAS cables to the storage drive
backplane from the Oracle Storage 12 Gb/s SAS PCIe RAID HBA [5].
To ensure proper SAS cable connections, see
Cables" on page
4.
Return the server to operation.
a.   
Install the fan assembly door top cover.
See
"Install the Fan Assembly Door" on page
b.   
Install the fan modules and close the fan assembly door.
See
"Install a Fan Module" on page
c.   
Install all storage drives into the storage drive cage.
See
"Install an HDD or SSD Storage Drive" on page
Return the server to the normal rack position.
d.   
See
"Return the Server to the Normal Rack Position" on page
e.   
Reconnect the power cords to the power supplies, and power on the server.
See
"Reconnect Power and Data Cables" on page 233
Server" on page
IMPORTANT: When the disk backplane is replaced, the key identity properties (KIP)
Note -
of the disk backplane is programmed by Oracle ILOM to contain the same KIP as the other
quorum member components. If you have removed other quorum member components,
you might need to manually program the product serial number (PSN) into the new disk
backplane. For more information, refer to
Update" on page
53.
Install the Storage Drive Backplane for Twelve-Drive Systems
171.
92.
233. Verify that the power supply AC OK LED is lit.
"FRU Key Identity Properties (KIP) Automated
"Install SAS Storage Drive
228.
78.
231.
and
"Power On the
Servicing FRUs
157