Identify and Remove a Faulty DIMM
See
b.   
Extend the server into the maintenance position.
See
Attach an antistatic wrist strap to your wrist and then to a metal area on the
c.   
chassis.
See
d.   
Remove the server top cover.
See
e.   
Swivel the air baffle into the upright position to allow access to DIMMs.
2.
Identify and note the location of the faulty DDR4 DIMM by pressing the Fault
Remind button on the motherboard I/O card.
See
"Using the Server Fault Remind Button" on page
Faulty DIMMs are identified with a corresponding amber LED on the motherboard.
If the DIMM fault LED is off, then the DIMM is operating properly.
If the DIMM fault LED is on (amber), then the DIMM is faulty and should be replaced [1].
110
Oracle Server X5-2L Service Manual • May 2015
"Powering Down the Server" on page
"Extend the Server to the Maintenance Position" on page
"Electrostatic Discharge Safety" on page
"Remove the Server Top Cover" on page
55.
61.
52.
64.
108.