Maintenance
item No.
U101
Setting the other high voltages
Description
Sets the developing bias control voltage, the transfer control voltage, and the separation control voltage or
checks the output of these voltages.
Purpose
To check or change the developing bias, the transfer voltage, and the separation voltage.
Method
Press the start key. The screen for selecting an item is displayed.
Display
DEV BIAS SET
TC SET
AC SET
Setting: developing bias control voltage
1. Press the DEV BIAS SET on the touch panel of the screen for selecting an item.
2. Select an item to be set.
Display
DB DATA
DB DATA2
3. Change the setting using the cursor up/down keys.
Increasing the setting makes the image darker; decreasing it makes the image lighter.
4. Press the start key. The value is set.
Setting: transfer bias control voltage
1. Press the TC SET on the touch panel of the screen for selecting an item.
2. Select an item to be set.
Display
TC DATA
TC DATA (DUP)
TC ON
3. Change the setting using the cursor up/down keys.
Increasing the setting makes the transfer voltage higher, and decreasing it makes the voltage lower.
Press the TC ON on the touch panel. The currently set transfer voltage is output. To stop the transfer
voltage output, press the stop/clear key.
4. Press the start key. The value is set.
Setting: separation bias control voltage
1. Press the AC SET on the touch panel of the screen for selecting an item.
2. Select an item to be set.
Display
AC DATA
AC DATA (DUP)
3. Change the setting using the cursor up/down keys.
Increasing the setting makes the separation voltage higher, and decreasing it makes the voltage lower.
4. Press the start key. The value is set.
Interrupt copy mode
While this maintenance item is being performed, copying from an original can be made in interrupt copy mode.
Completion
Press the stop/clear key at the screen for selecting an item. The screen for maintenance item No. is displayed.
Description
Description
Setting of developing bias control voltage
Setting and output check of transfer control voltage
Setting of separation control voltage
Description
Developing bias step control final voltage
Developing bias step control initial voltage
Description
Transfer control voltage for simplex copying
Transfer control voltage for duplex copying
Transfer voltage output ON
Description
separation control voltage for simplex copying 0 to 255
separation control voltage for duplex copying
Setting range
Initial setting
0 to 255
207
0 to 255
52
Setting range
Initial setting
0 to 255
210
0 to 255
210
Setting range
Initial setting
200
0 to 255
230
2BC/D
1-4-31