Maintenance
item No.
U907
Checking and resetting the count value on each ejection location
Description
Displays and resets the count value of ejected sheets on each ejection location.
Purpose
Checks the replacement period for maintenance parts. Also resets the count value after replacing the
maintenance parts.
Method
Press the start key. The screen for selecting an item is displayed.
The count value on each ejection location is displayed
Display
STRAIGHT
SWITCH BACK
AUTO DUPLEX
Clearing
1. Select the count to be cleared. The selected item is displayed in reverse.
To clear the counts for all, press the reset key.
2. Press the start key. The count is cleared, When clearing all counts, the screen for selecting a maintenance
item No. is displayed.
Completion
To exit this maintenance item without changing the count, press the stop/clear key. The screen for selecting a
maintenance item No. is displayed.
U908
Changing the total counter value
Description
Displays, clears and changes the total counter value.
Purpose
To check the total counter value.
Method
Press the start key. The screen for total count value is displayed.
Display
TOTAL COUNT
TOTAL COUNT (MACHINE)
Clearing
1. Select the count to be cleared. The selected item is displayed in reverse.
2. Press the reset key.
3. Press the start key. The count is cleared, and the screen for selecting a maintenance item No. is displayed.
Completion
To exit this maintenance item without changing the count, press the stop/clear key. The screen for selecting a
maintenance item No. is displayed.
U909
Checking/clearing the fixing web count
Description
Displays and clears the count of the fixing web roller operation.
Purpose
To clear the fixing web counts after replacing the fixing web roller during maintenance or for other reasons.
Method
Press the start key.
Clearing
1. Press the reset key.
2. Press the start key. The value is cleared. The screen for selecting a maintenance item No. is displayed.
Setting
1. Enter a six-digit value using the numeric keys.
2. Press the start key. The value is set. The screen for selecting a maintenance item No. is displayed.
Completion
To exit this maintenance item without changing the count, press the stop/clear key. The screen for selecting a
maintenance item No. is displayed.
Description
Description
Straight ejection count
Reversed ejection count
Duplex tray ejection count
Description
Electronic total counter value
Mechanical total counter value entered at the beginning
2BC/D