Kyocera Mita KM-4530 Service Manual page 107

Table of Contents

Advertisement

2BC/D-1
Maintenance
item No.
U194
Setting the fixing web drive
Description
Sets the interval (number of copies) for turning on the fixing web solenoid.
Purpose
To be executed when the fixing web roller becomes extremely soiled.
Method
Press the start key. The screen for adjustment is displayed.
Setting
1. Change the setting using the cursor up/down keys.
Description
Interval for turning on the fixing web solenoid
2. Press the start key. The value is set.
Completion
To exit this maintenance item without changing the current value, press the stop/clear key. The screen for
selecting a maintenance item No. is displayed.
U196
Turning the fixing heater on
Description
Turns the fixing heater M or S on.
Purpose
To check fixing heaters turning on.
Method
1. Press the start key. The screen for selecting an item is displayed.
2. Select the heater to be turned on. The selected heater turns on for 2 s and then turns off.
Display
MAIN
SUB
Completion
Press the stop/clear key when fixing motors M and S are off. The screen for selecting the maintenance item No.
is displayed.
U198
Setting the fixing phase control
Description
Sets the use of fixing phase control to reduce electrical noise generated by the copier.
Purpose
Normally no change is necessary. If electrical noise generated by the copier causes flickering of the lights
around the copier, select fixing phase control to reduces the noise.
Method
Press the start key. The screen for adjustment is displayed.
Setting
1. Select ON or OFF. The selected item is displayed in reverse.
Display
ON
OFF
Initial setting: ON (220-240 V specifications) / OFF (120 V specifications)
2. If you select ON, use the ∗ or # key to set 0 (100 V system fixing heater phase control) or 1 (200 V system
fixing heater phase control).
3. Press the start key. The value is set.
Completion
To exit this maintenance item without changing the current value, press the stop/clear key. The screen for
selecting a maintenance item No. is displayed.
1-4-40
Description
Setting range
1 to 40
Description
Fixing heater M (FH-M)
Fixing heater S (FH-S)
Description
Fixing phase control present
Fixing phase control absent
Initial setting
30