Kyocera Mita KM-4530 Service Manual page 259

Table of Contents

Advertisement

1-6-9 Fixing section
(1) Detaching and refitting the fixing unit
Follow the procedure below to check or replace the fixing unit.
Procedure
1. Open the front cover, tilt the paper conveying
unit release lever down, and pull out the
paper conveying unit.
2. Open the eject cover.
3. Remove the two screws holding the fixing unit
and then the unit from the conveying unit.
4. Check or replace the fixing unit and refit all
the removed parts.
(2) Detaching and refitting the fixing heaters M and S
Follow the procedure below to replace the fixing heaters M and S.
Procedure
1. Remove the fixing unit.
2. Remove the two screws holding the fixing
front cover and then the cover.
Eject cover
Figure 1-6-101
Fixing front cover
Figure 1-6-102
2BC/D
Fixing unit
1-6-55

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Km-5530

Table of Contents