1-6-3 Optical section
(1) Detaching and refitting the exposure lamp
Follow the procedure below to replace the exposure lamp.
Procedure
1. Open the DF.
2. Remove the two screws holding the upper
right cover and then the cover.
3. While taking care not to touch the shading
plate or rear face of the contact glass, remove
the contact glass.
4. Move the mirror 1 frame to the cutouts at the
center of the machine.
* When moving the mirror 1 frame, do not
touch the exposure lamp nor inverter PCB.
5. Disconnect the exposure lamp connector
from the inverter PCB.
6. Remove the two screws holding the exposure
lamp and then the lamp.
7. Replace the exposure lamp and refit all the
removed parts.
Figure 1-6-38
Exposure lamp
Connector
Figure 1-6-39
2BC/D
Upper right
cover
1-6-21