3. Remove the developing duct cover and
middle right cover.
4. Cut out the aperture plate on the middle right
cover using nippers.
5. Pass the 4-pin connector of the key counter
through the apertures in the key counter
cover retainer and middle right cover, and
insert into the 4-pin connector inside the
machine.
6. Seat the projection of the key counter cover
retainer in the aperture in the middle right
cover, and fasten them both to the machine
using the two screws.
7. Refit all the removed parts.
8. Fit the key counter cover with the key counter
assembly inserted to the key counter cover
retainer on the machine.
9. Insert the key counter into the key counter
assembly.
10. Turn the main switch on and enter the
maintenance mode.
11. Run maintenance item U204 and select
"KEY-COUNTER."
12. Exit the maintenance mode.
13. Check that the message requesting the key
counter to be inserted is displayed on the
touch panel when the key counter is pulled
out.
14. Check that the counter counts up as copies
are made.
Aperture
4-pin connector
4-pin connector
Middle right cover
Key counter cover retainer
(66060022)
M4 × 30 screw
(B1304300)
Key counter cover
M4 × 20 screw
M4 × 6 screw
(B4304200)
(B4104060)
Figure 1-3-33
2BC/D
1-3-17