Kyocera Mita KM-4530 Service Manual page 167

Table of Contents

Advertisement

2BC/D
Code
Contents
C1100
Deck right lift motor problem
[Drawer 3]
• When the drawer 3 is inserted, the
Deck lift limit switch 1 does not turn
on within 33 s of the deck right lift mo-
tor turning on.
• During copying, the deck lift limit
switch 1 does not turn on within 200
ms of the deck right lift motor turning
on.
C1110
Deck left lift motor problem
[Drawer 4]
• When the drawer 4 is inserted, the
deck lift limit switch 2 does not turn on
within 33 s of the deck left lift motor
turning on.
• During copying, the deck lift limit
switch 2 does not turn on within 200
ms of the deck left lift motor turning
on.
1-5-24
Causes
Check procedures/corrective measures
Broken gears or
Replace the deck right lift motor.
couplings of the
deck right lift mo-
tor.
Defective deck
Check for continuity across the coil. If
right lift motor.
none, replace the deck right lift motor.
Poor contact of
Reinsert the connector. Also check for con-
the deck right lift
tinuity within the connector cable. If none,
motor connector
repair or replace the cable.
terminals.
Defective deck lift
Check if CN8-2 on the engine PCB goes
limit switch 1.
low when the deck right lift limit switch 1 is
turned off. If not, replace the deck lift limit
switch 1.
Poor contact of
Reinsert the connector. Also check for con-
the deck lift limit
tinuity within the connector cable. If none,
switch 1 connec-
repair or replace the cable.
tor terminals.
Broken gears or
Replace the deck left lift motor.
couplings of the
deck left lift motor.
Defective deck left
Check for continuity across the coil. If
lift motor.
none, replace the deck left lift motor.
Poor contact of
Reinsert the connector. Also check for con-
the deck left lift
tinuity within the connector cable. If none,
motor connector
repair or replace the cable.
terminals.
Defective deck left
Check if CN26-8 on the engine PCB goes
lift limit switch 2.
low when the deck lift limit switch 2 is
turned off. If not, replace the deck lift limit
switch 2.
Poor contact of
Reinsert the connector. Also check for con-
the deck lift limit
tinuity within the connector cable. If none,
switch 2 connec-
repair or replace the cable.
tor terminals.
Remarks