Maintenance
item No.
U266
Setting the number of days after which to automatically delete documents
Descrioption
Sets the number of days to save documents on the HDD before automatically deleting.
Purpose
To change the number of days to retain data that is saved within the auto-delete area of the HDD before
automatically deleting.
Method
Press the start key. The current setting is displayed.
Setting
1. Change the setting using the cursor up/down keys.
Description
Number of days after which to automatically delete documents
2. Press the start key. The value is set, and the screen for selecting a maintenance item No. is displayed.
Completion
To exit this maintenance item without changing the current setting, press the stop/clear key. The screen for
selecting a maintenance item No. is displayed.
U275
Setting the number of sheets for duplex circulation
Descrioption
Sets the number of sheets for circulation in the duplex copy mode.
Purpose
To reduce the number of sheets for circulation if paper jams occur frequently in the duplex copy mode.
Method
1. Press the start key. The screen for selecting an item is displayed.
2. Select an item to be set.
Display
MODE0
MODE1
Initial setting: MODE0
3. Press the start key. The setting is set, and the screen for selecting a maintenance item No. is displayed.
Completion
To exit this maintenance item without changing the current setting, press the stop/clear key. The screen for
selecting a maintenance item No. is displayed.
U277
Setting auto application change time
Description
Sets the time that passes until the machine starts automatically printing after completing copying or operation
when the machine is used as a printer (only if the printer kit is installed).
Purpose
According to user request, changes the setting.
Method
Press the start key. The current setting is displayed.
Setting
1. Change the setting using the cursor up/down keys.
Description
Switching time
The setting can be changed by 30 s per step.
2. Press the start key. The value is set, and the screen for selecting a maintenance item No. is displayed.
Completion
To exit this maintenance item without changing the current setting, press the stop/clear key. The screen for
selecting a maintenance item No. is displayed.
Description
Description
Circulation of five sheets
Circulation of four sheets
Setting range
Initial setting
30 to 270 (s)
30
Setting range
Initial setting
0 to 7 (days)
7