2BC/D-1
Installing the drum.
1. Remove the two connectors from the main
charger unit.
2. Use a flat-blade screwdriver to loosen the pin at
the rear of the main charger unit and remove the
main charger unit from the image formation unit.
3. Remove the screw each from the front drum
positioning plate and the rear drum positioning
plate and remove the plates.
4. Fit the front drum positioning plate and the rear
drum positioning plate to the drum, and set them
on the image formation unit.
5. Secure the front drum positioning plate and the
rear drum positioning plate with a screw each.
* Fit the drum so that the side with the thin shaft of
the drum flange is placed on the front side of the
machine and the side with the thick shaft of the
drum flange is placed on the rear side.
6. Refit the main charger unit and the developing
unit to their original positions.
7. Refit the image formation unit to their original
positions.
* Be sure to reconnect the connector of the image
formation unit.
1-3-8
Connector
Connector
Figure 1-3-16
Front drum
positioning plate
Figure 1-3-17
Front drum
positioning plate
Figure 1-3-18
Main charger unit
Rear drum
positioning plate
Rear drum
positioning plate
Drum
Pin