Kyocera Mita KM-4530 Service Manual page 376

Table of Contents

Advertisement

2BC/D-1
Maintenance
Section
part/location
Optical section
Slit glass
Contact glass
Mirror 1
Mirror 2 and mirror 3
Lens
Reflector
Exposure lamp
Optical rail
Original size detection
sensor
Maintenance
Section
part/location
Developing
Developing unit
section
Lower developing
cover
Developing unit
upper seal
Seals and sponges
Gears
Developing duct
Developing duct filter
Sub hopper coupling
Maintenance
Section
part/location
Image formation
Drum
section
Main charger unit
Charger wire cleaning
pad
Grid wire cleaning pad
Charger wire
Main charger grid
Cleaning lamp
Pre-cleaning lamp
2-4-18
2-4-16
Method
Maintenance cycle
Clean
Every service
Clean
Every service
Clean
Every service
Clean
Every service
Clean
Every service
Clean
Every service
Check and replace
Every service
Grease
Every service
Clean
Every service
Method
Maintenance cycle
Replace
Every service
Clean
Every service
Clean
Every service
Check and replace
Clean
Every service
Check
Every service
Grease
Every service
Clean
Every service
Replace
Every service
Check and Grease
Every service
Method
Maintenance cycle
Replace
Every service
Clean
Every service
Replace
Every service
Replace
Every service
Replace
Every service
Clean or replace
Every service
Clean
Every service
Clean
Every service
Points and cautions
Clean with alcohol and then
a dry cloth.
Clean with alcohol and then
a dry cloth.
Clean with alcohol and then
a dry cloth.
Clean with alcohol and then
a dry cloth.
Clean with a dry cloth.
Clean with a dry cloth.
Replace if an image problem
occurs or after the exposure
lamp has been lit for 1,000 hours.
Check noise and shifting and
then apply scanner rail grease
PG671.
Clean with alcohol or a dry cloth.
Points and cautions
Vacuum.
Vacuum or clean with a dry cloth. 1-6-46
Replace if deformation, waviness
or break of the seal is found.
Check for vacuum and breakage.
Check noise and the levels of
wear.
Apply grease TMP1-200G.
Vacuum.
Check noise and Apply grease
TMP1-200G.
Points and cautions
Clean the shield with a wet cloth
and then a dry cloth.
Clean the shield with a wet cloth
and then a dry cloth. Replace if
damage or folds are serious.
Clean with a dry cloth.
Clean with a dry cloth.
Page
1-6-21
Page
1-6-44
1-6-47
Page
1-6-42
1-6-39
1-6-41
1-6-41
1-6-39
1-6-39

Hide quick links: