(4) Detaching and refitting the press roller
Follow the procedure below to replace the press roller.
Procedure
1. Remove the heat roller (see page 1-6-57).
2. Remove the screw holding the guide plate
and then the plate.
3. Remove the press roller from the fixing unit.
4. Remove the E ring on either the front or rear
end of the press roller and pull out the press
roller shaft.
5. Replace the press roller and all the removed
parts.
Guide plate
Figure 1-6-109
press roller
Figure 1-6-110
E ring
Press roller
Figure 1-6-111
2BC/D
E ring
Press roller shaft
1-6-59