2BC/D
11. Lock down the upper and lower merge guides
with the four M3 × 6 TP-A bronze screws.
12. Attach the interlock switch backstop to the
right rear lower cover with the M4 × 12 flat
head screw.
13. Reattach the developing duct cover, middle
right cover and right cover.
Note: When reattaching the developing unit
duct cover, be sure to reconnect the 2-pin
connector to the cooling fan.
14. Pull out the retaining rail from the side deck
and insert into the paper feed section lower
cover of the copier.
1-3-26
Upper merge guide
Lower merge guide
M3 × 6 TP-A bronze screws
Figure 1-3-54
M4 × 12 flat head screw
Figure 1-3-55
Side deck
Retaining rail
Figure 1-3-56
Right rear lower cover
Interlock switch backstop
Paper feed section lower cover