Kyocera Mita KM-4530 Service Manual page 132

Table of Contents

Advertisement

Maintenance
item No.
U344
Setting preheat/energy saver mode
Description
Changes the control for preheat/energy saver mode.
Purpose
According to user request, selects which has priority, the recovery time from preheat or energy saver.
Method
Press the start key. The screen for selecting an item is displayed.
Setting
1. Select control mode. The selected item is displayed in reverse.
Display
INSTANT READY
ENERGY STAR
E 2000
TOP RUNNER
Initial setting: ENERGY STAR
2. Press the start key. The setting is set, and the screen for selecting a maintenance item No. is displayed.
Completion
Press the stop/clear key at the screen for selecting an item. The screen for selecting a maintenance item No. is
displayed.
U345
Setting the value for maintenance due indication
Description
Sets when to display a message notifying that the time for maintenance is about to be reached, by setting the
number of copies that can be made before the current maintenance cycle ends.
When the difference between the number of copies of the maintenance cycle and that of the maintenance
count reaches the set value, the message is displayed.
This maintenance mode is effective for only Japanese specification.
Description
Description
The fixing control temperature is not lowered and only the display on
the operation panel is turned off.
The fixing control temperature is lowered by 30°C/86°F and forced
stabilization is performed 30 seconds after exiting preheat.
The fixing control temperature is lowered by 30°C/86°F and forced
stabilization is performed 30 seconds after exiting preheat.
Control in accordance with Top Runner is performed.
2BC/D
1-4-63

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Km-5530