Kyocera Mita KM-4530 Service Manual page 194

Table of Contents

Advertisement

Problem
(37)
Broken duplex reversing
The duplex revers-
clutch coil.
ing clutch does not
Poor contact in the duplex
operate.
reversing clutch connector
terminals.
Defective engine PCB.
(38)
Broken deck feed clutch
The deck feed
coil.
clutch does not op-
Poor contact in the deck
erate.
feed clutch connector ter-
minals.
Defective engine PCB.
(39)
Broken bypass solenoid
The bypass sole-
coil.
noid does not oper-
Poor contact in the bypass
ate.
solenoid connector termi-
nals.
Defective engine PCB.
(40)
Broken duplex eject
The duplex eject
switching solenoid coil.
switching solenoid
Poor contact in the duplex
does not operate.
eject switching solenoid
connector terminals.
Defective engine PCB.
(41)
Broken duplex pressure
The duplex pressure
release solenoid coil.
release solenoid
Poor contact in the duplex
does not operate.
pressure release solenoid
connector terminals.
Defective engine PCB.
(42)
Broken feedshift solenoid
The feedshift sole-
coil.
noid does not oper-
Poor contact in the
ate.
feedshift solenoid connec-
tor terminals.
Defective engine PCB.
Causes
Check for continuity across the coil. If none, replace the duplex
reversing clutch.
Reinsert the connector. Also check for continuity within the con-
nector cable. If none, remedy or replace the cable.
Run maintenance item U032 and check if CN6-12 on the engine
PCB goes low. If not, replace the engine PCB.
Check for continuity across the coil. If none, replace the deck
feed clutch.
Reinsert the connector. Also check for continuity within the con-
nector cable. If none, remedy or replace the cable.
Run maintenance item U032 and check if CN26-14 on the en-
gine PCB goes low. If not, replace the engine PCB.
Check for continuity across the coil. If none, replace the bypass
solenoid.
Reinsert the connector. Also check for continuity within the con-
nector cable. If none, remedy or replace the cable.
Run maintenance item U033 and check if CN9-B3 on the en-
gine PCB goes low. If not, replace the engine PCB.
Check for continuity across the coil. If none, replace the duplex
eject switching solenoid.
Reinsert the connector. Also check for continuity within the con-
nector cable. If none, remedy or replace the cable.
Run maintenance item U033 and check if CN6-7 and CN6-8 on
the engine PCB go low. If not, replace the engine PCB.
Check for continuity across the coil. If none, replace the duplex
pressure release solenoid.
Reinsert the connector. Also check for continuity within the con-
nector cable. If none, remedy or replace the cable.
Run maintenance item U033 and check if CN6-9 and CN6-10 on
the engine PCB go low. If not, replace the engine PCB.
Check for continuity across the coil. If none, replace the feedshift
solenoid.
Reinsert the connector. Also check for continuity within the con-
nector cable. If none, remedy or replace the cable.
Run maintenance item U033 and check if CN3-A7 and CN3-A8
on the engine PCB goes low. If not, replace the engine PCB.
Check procedures/corrective measures