Kyocera Mita KM-4530 Service Manual page 195

Table of Contents

Advertisement

2BC/D
Problem
(43)
Broken fixing web solenoid
The fixing web sole-
coil.
noid does not oper-
Poor contact in the fixing
ate.
web solenoid connector
terminals.
Defective engine PCB.
(44)
Poor contact in the clean-
The cleaning lamp
ing lamp connector termi-
does not turn on.
nals.
Defective cleaning lamp.
Defective engine PCB.
(45)
Poor contact in the expo-
The exposure lamp
sure lamp connector termi-
does not turn on.
nals.
Defective inverter PCB.
Defective scanner drive
PCB.
(46)
Defective inverter PCB.
The exposure lamp
does not turn off.
Defective scanner drive
PCB.
(47)
Broken wire in fixing
Fixing heater M or S
heater M or S.
does not turn on
Fixing unit thermostat trig-
(C6000).
gered.
(48)
Dirty sensor part of the
Fixing heater M or S
fixing unit thermistor.
does not turn off.
Defective engine PCB.
(49)
Broken main charger wire.
Main charging is not
Leaking main charger
performed (C5100).
housing.
Poor contact in the high
voltage transformer PCB
connector terminals.
Defective engine PCB.
Defective high voltage
transformer PCB.
1-5-48
Causes
Check for continuity across the coil. If none, replace the fixing
web solenoid.
Reinsert the connector. Also check for continuity within the con-
nector cable. If none, remedy or replace the cable.
Run maintenance item U033 and check if CN14-4 on the engine
PCB goes low. If not, replace the engine PCB.
Reinsert the connector. Also check for continuity within the con-
nector cable. If none, remedy or replace the cable.
Check for continuity. If none, replace the cleaning lamp.
If the cleaning lamp turns on when CN4-11 on the engine PCB is
held low, replace the engine PCB.
Reinsert the connector. Also check for continuity within the con-
nector cable. If none, remedy or replace the cable.
If the exposure lamp turn on when CN1-5 and CN1-6 on the in-
verter PCB are held low, replace the inverter PCB.
If the exposure lamp turn on when CN3-1 and CN3-2 on the
scanner motor PCB are held low, replace the scanner drive
PCB.
If the exposure lamp does not turn off with CN1-5 and CN1-6 on
the inverter PCB high, replace the inverter PCB.
If CN3-1 and CN3-2 on the scanner motor PCB are always low,
replace the scanner drive PCB.
Check for continuity across each heater. If none, replace the
heater (see page 1-6-55).
Check for continuity across thermostat. If none, remove the
cause and replace the thermostat.
Check visually and clean the thermistor sensor parts.
If fixing heater M/S stays on while CN2-5 and CN2-6 on the en-
gine PCB go high, replace the engine PCB.
See page 1-5-33.
Check procedures/corrective measures

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Km-5530

Table of Contents