7B-71 Air Conditioning System:

Sunload Sensor Inspection

1) Remove sunload sensor. Refer to "Sunload Sensor
Removal and Installation: ".
2) Light over the sensor vertically with an incandescent
lamp of approximately 100 watt.
3) The distance between the sensor and the lamp
should be approximately 100 mm (3.94 in.).
4) Measure the voltage between the terminals with the
(+) probe on the terminal "a" and the (–) probe on the
terminal "b".
5) Make sure if the voltage is approximately 0.38 – 0.42
V. If not, replace the sensor with the new one.
Sunload sensor specifications
"a" – "b": Approx. 0.38 – 0.42 V
Inside Air Temperature Sensor Removal and
Installation
Removal
1) Disconnect negative cable (–) at battery.
2) Remove steering column hole cover.
3) Disconnect inside air temperature sensor connector
(1) and aspirator hose (2).
4) Remove inside air temperature sensor (3) from
vehicle.
Installation
Reverse removal procedure.
S5JB0A7206053
"b"
"a"
I5JB0A720053-01
S5JB0A7206054
1
3
2
I5JB0A720054-01

Inside Air Temperature Sensor Inspection

1) Remove Inside air temperature sensor referring to
"Inside Air Temperature Sensor Removal and
Installation: ".
2) Check resistance between terminals.
Inside air temperature sensor resistance
Approx. 1.7 kΩ ± 85 Ω at 25 °C (77 °F)
5.5
Resistance
1.7
Outside Air Temperature Sensor Removal and
Installation
Refer to "Outside Air Temperature Sensor Removal and
Installation (If Equipped): in Section 9C".

Outside Air Temperature Sensor Inspection

Refer to "Outside Air Temperature Sensor Inspection (If
Equipped): in Section 9C".
Air Flow Control Actuator Removal and
Installation
Refer to "Air Flow Control Actuator Removal and
Installation: in Section 7A".

Air Flow Control Actuator Inspection

Refer to "Air Flow Control Actuator Inspection: in
Section 7A".
S5JB0A7206055
0
25
32
77
F
Temperature
I5JB0A720055-01
S5JB0A7206056
S5JB0A7206057
S5JB0A7206058
S5JB0A7206059