5) Start engine and keep engine speed at 1,500 rpm.
Then, operate A/C system.
6) Charge A/C system with refrigerant in vapor state. At
this time, refrigerant container should be held
upright.
7) When refrigerant container (3) is emptied, the use
following procedure to replace it with a new
refrigerant container (3).
a) Close low pressure valve.
b) Replace empty container (3) with a refrigerant
container which has been charged with
refrigerant. When using refrigerant container tap
valve (4), use the following procedure for
replacement.
i)
Retract needle (1) and remove refrigerant
container tap valve (4) by loosening its plate
nut (2).
ii) Install previously-removed refrigerant
container tap valve (4) to a new refrigerant
container (3).
c) Purge any air existing in center charging hose.
When using refrigerant container tap valve, use
the following procedure to purge air.
i)
Once fully tighten refrigerant container tap
valve and then loosen (open) plate nut
slightly.
ii) Open low pressure valve of manifold gauge
set a little.
iii) As soon as refrigerant comes out with a
"hiss" (1) through a clearance between
refrigerant container and tap valve, tighten
plate nut as well as manifold gauge set low
pressure valve.
iv) Turn handle of tap valve clockwise so that its
needle is screwed into the new container to
make a hole for refrigerant flow.
8) After the system has been charged with specified
amount (570 ± 30 g) of refrigerant or when low
pressure gauge and high pressure gauge have
indicated the following specified value, close low
pressure side valve on manifold gauge set.
Low side and high side pressure example
Gauges should read as follows when ambient
temperature is 30 °C (86 °F)
Pressure
on high pressure gauge
Pressure
on low pressure gauge
IYSQ01720015-01
Removal of Manifold Gauge Set
WARNING
!
High pressure side is under high pressure.
Therefore, be careful not to get injured
especially on your eyes and skin.
For the A/C system charged with the specified amount of
refrigerant, remove manifold gauge set as follows:
1) Close low pressure side valve of manifold gauge set.
(The high pressure side valve is closed continuously
during the process of charging.)
2) Close refrigerant container valve.
3) Stop engine.
4) Using shop rag, remove charging hoses from service
valves. This operation must be performed quickly.
5) Put caps on service valves.
Air Conditioning System:
IYSQ01720016-01
M16 engine model:
1150 – 1410 kPa
11.5 – 14.1 kg/cm
2
164 – 201 psi
J20 engine model:
1300 – 1630 kPa
13.0 – 16.3 kg/cm
185 – 232 psi
M16 engine model:
280 – 410 kPa
2.8 – 4.1 kg/cm
2
40 – 58 psi
J20 engine model:
250 – 370 kPa
2.5 – 3.7 kg/cm
2
36 – 53 psi
7B-62