7B-21 Air Conditioning System:
7) Wait for ten minutes to stabilize A/C operation.
8) Keep all windows, doors and engine food open.
9) With about 20 mm (0.8 in.) of dry bulb thermometer
(1) put right in front of center ventilation louver and a
wet and dry bulb thermometer (2) near air inlet (3) of
HVAC unit.
10) Check for each pressure of low side and high side if it is within shaded range of graph. If each gauge reading is out
of specified pressure, correct defective part referring to the table.
Low side and high side pressure example, gauges should read as follows when ambient temperature is 30
°C (86 °F)
M16 engine model
Pressure on high pressure gauge (HI): 1150 – 1410 kPa (11.5 – 14.1 kg/cm
Pressure on high pressure gauge (LO): 280 – 410 kPa (2.8 – 4.1 kg/cm
J20 engine model
Pressure on high pressure gauge (HI): 1300 – 1630 kPa (13.0 – 16.3 kg/cm
Pressure on high pressure gauge (LO): 250 – 370 kPa (2.5 – 3.7 kg/cm
NOTE
Pressure registered on gauge varies with ambient temperature. Therefore, use the graphs when
determining if pressures are normal or not.
[A]
psi
kPa
kg/cm
312.9 2200
22
298.7 2100
21
284.4
2000
20
270.2
1900
19
256.0
1800
18
241.7
1700
17
227.5
1600
16
213.3
1500
15
199.1
1400
14
184.9
1300
13
170.6
1200
12
151.4
1100
11
142.2
1000
10
128.0
900
9
113.8
800
8
99.5
700
7
85.3
600
6
71.1
500
5
56.9
400
4
42.7
300
3
28.4
200
2
14.2
100
1
0
2
"A"
"B"
"C"
"D"
25
30
35
77
86
95
Ambient Temperature
[A]: M16 engine model
[B]: J20 engine model
[B]
psi
kPa
%
312.9 2200
298.7 2100
284.4
270.2
256.0
241.7
70
227.5
213.3
199.1
30
184.9
170.6
151.4
142.2
128.0
113.8
99.5
85.3
71.1
70
56.9
30
42.7
28.4
14.2
C
F
1
3
2
, 164 – 201 psi)
2
, 40 – 58 psi)
2
, 185 – 232 psi)
2
, 36 – 53 psi)
2
kg/cm
22
21
2000
20
1900
19
1800
18
1700
17
"A"
1600
16
1500
15
1400
14
1300
13
1200
12
"B"
1100
11
1000
10
900
9
800
8
700
7
600
6
"C"
500
5
400
4
300
3
200
2
100
1
"D"
0
25
30
77
86
Ambient Temperature
2
I5JB0A720011-01
%
70
30
70
30
35
C
95
F
I5JB0A720012-04

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents