Brocade Communications Systems Brocade 8/12c User Manual page 874

Brocade network advisor san user manual v11.1x (53-1002167-01, may 2011)
Hide thumbs Also See for Brocade 8/12c:
Table of Contents

Advertisement

29
Adding a policy monitor
8. To set policy monitors for switches, select the SAN Switch Checks tab and complete the
830
following steps.
FIGURE 363
Add Policy Monitor dialog box, SAN Switch Checks tab
a. Select the Check if the product is configured to send events to this server check box to
determine if the Management application server is registered as an SNMP recipient and
Syslog recipient.
b. Select the Check for redundant connections to neighboring switches check box to
determine if there are at least the minimum number of configured ISLs between each
switch pair.
The default is 2.
c.
Enter the minimum number of connections allowed between a switch pair in the Minimum
Connections field.
The default recommended is 2.
d. Select the Check if the product is configured to send Upload Failure Data Capture to an
FTP server check box to determine the following configurations:
Upload Failure Data Capture is enabled on the selected switches
Configured FTP Server is accessible
You have write permission to the directory.
e. Select the switches to which you want to apply this policy in the Available Switches table
and click the right arrow button.
The selected switches display in the Selected Switches table.
Brocade Network Advisor SAN User Manual
53-1002167-01

Advertisement

Table of Contents
loading

This manual is also suitable for:

Network advisor 11.1.xBrocade bladesystem 4/24

Table of Contents