fcid-last-byte

Use the fcid-last-byte command to allocate the last byte FCID for the fabric address. To disable the
configuration or to revert to factory defaults, use the no form of the command.
Syntax Description
last-byte-fcid
Defaults
None.
Command Modes
FICON configuration submode.
Command History
Release
1.3(1)
3.0(1)
Usage Guidelines
This is an optional configuration. If you are not sure of the EBCDIC format to be used, we recommend
retaining the us-canada (default) option.
Examples
The following example assigns the last byte FCID for the fabric address.
switch# config terminal
switch(config)# ficon vsan 2
switch(config-ficon)# fcid-last-byte 12
The following example removes the configured last byte FCID for the fabric address and reverts to the
default.
switch# config terminal
switch(config)# ficon vsan 2
switch(config-ficon)# no fcid-last-byte 3
Related Commands
Command
show ficon
ficon vsan vsan-id
OL-18089-01, Cisco MDS NX-OS Release 4.x
fcid-last-byte last-byte-id
no fcid-last-byte last-byte-id
Specifies the last-byte FCID range from 0 to 250.
Modification
This command was introduced.
This command was deprecated.
Description
Displays configured FICON details.
Enables FICON on the specified VSAN.