Section C - Electrics
Engine and Power Control
Engine Start/Stop
Engine Start/Stop
Engine Run
K Fig 7. Circuits ( T C-69)
When the ignition switch is set to position I, there is a +24
V supply at the engine stop switch C119. The fuel lift pump
K Ignition
energises.
Power
Supply
and
Distribution ( T C-66)
When the engine stop switch is set to RUN the engine shut
down relay R4 energises. The contacts close and +24 V is
connected to the engine ECU C251 pin 61. The engine
ECU enables engine running.
At the same time the input at the MECU C016-J2 pin 32
goes low. This informs the MECU of the engine stop switch
state.
Engine Stop
When the engine stop switch is set to STOP the engine
shut down relay R4 de-energises. The contacts open and
the input at the engine ECU C251 pin 61 goes low. The
engine ECU disables engine running.
At the same time the input at the MECU C016-J2 pin 32
goes high. This informs the MECU of the engine stop
switch state.
When the ignition switch is set to position 0, the fuel lift
K Ignition Power Supply and
pump de-energises.
Distribution ( T C-66)