Component Location
Additional work lights (optional) are mounted on the roof of
the cab pointing forward for increased lighting.
Overview
The work lights are operated from a 2 position rocker
switch in the right hand console.
Wires and Connectors
K Fig 6. ( T C-130)
The 2 position rocker switch (C114) receives a feed on pin
2 from fuse 16 of the main fuse box module (C100 X4).
Position 1 is the OFF position for the lights.
Position 2 connects power across the switch to pin 3 which
feeds 24V to the cab work lights (C055, C056) through the
cab roof connector (IC07). The cab work lights switch ON.
C055-1, C055-2
C056-1, C056-2
Fig 5. Harness connectors C055, C056 and C114
C-129
Cab Work Lights
C114
C129480-C2.eps
9813/5100-1
Section C - Electrics
Cab Systems and Lighting
Cab Work Lights
C-129