Specific Gravity Testing
The specific gravity of the electrolyte gives an idea of the
state of charge of the battery. Readings should be taken
using a hydrometer, when the electrolyte temperature is
15°C (60°F). If the battery has recently been on charge,
wait approximately one hour (or slightly discharge the
battery) to dissipate the surface charge before testing.
Ambient temperature up to 27°C (80°F)
Ambient temperature above 27°C (80°F)
C-151
Readings should be as tabulated and should not vary
between cells by more than 0.04. A greater variation
indicates an internal fault on that particular cell.
If the electrolyte temperature is other than 15°C (60°F) a
'correction factor' must be applied to the reading obtained.
Add 0.07 per 10°C (18°F) if the temperature is higher than
15°C (60°F) and subtract the same if the temperature is
lower.
Table 3. Specific Gravity at 15°C (60°F)
Fully Charged
1.270 - 1.290
1.240 - 1.260
9813/5100-1
Section C - Electrics
Charging System
Test Procedures
Half Discharged
Fully Discharged
1.190 - 1.210
1.110 - 1.130
1.170 - 1.190
1.090 - 1.110
C-151