1
Fig 27.
9
Withdraw feedback lever 35.
1
Fig 28.
10
Remove lever 36 from pin 37 (in the regulator body)
leaving pin 37A in position on the lever.
11
Draw out pilot piston 38 and spool 39.
12
Withdraw piston case 40, compensating piston 41
and compensating rod 42.
E-72
Note: 3 Piston case 40 can be removed by pressing
compensating rod 42 from the opposite side of regulator
body 1.
X
379450-C1
35
379460-C1
9813/5100-1
Section E - Hydraulics
Hydraulic Pump/Regulator
Regulator Dismantling and Assembly
E-72