Section E - Hydraulics
Hydraulic System
Hydraulic Operation and Schematics
Auxiliary Circuit
K Fig 15. ( T E-52)
For Schematic,
An auxiliary circuit gives a bi-directional flow to the
equipment being used:
The Option pedal 53 can be selected back or forward
depending on the direction the operator wants the
equipment to move.
Pilot pressure from the pedal 53 selects the auxiliary spool
via port pa2.
The hammer/auxiliary solenoid B is energised in aux mode
which does not allow pilot pressure to select the hammer/
auxiliary changeover valve 27.
Flow from pump 2 crosses the selected hammer spool and
exits the valve block at port A2.
E-51
9813/5100-1
E-51