AMC ↔ GND (A15–10 ↔ A14–12)
AMC ↔ GND (A15 10 ↔ A14 12)
AMH ↔ GND (A15–11 ↔ A14–12)
AMH ↔ GND (A15 11 ↔ A14 12)
HR ↔ GND (A14–4 ↔ A14–12)
HR ↔ GND (A14 4 ↔ A14 12)
ILL+ ↔ GND (A14–22 ↔ A14–12)
ILL ↔ GND (A14 22 ↔ A14 12)
BLW ↔ GND (A14 5 ↔ A14 12)
BLW ↔ GND (A14–5 ↔ A14–12)
GND ↔ Body ground (A14–12 ↔ Body
ground)
REC ↔ GND (A15–17 ↔ A14–12)
REC ↔ GND (A15 17 ↔ A14 12)
FRS ↔ GND (A15–16 ↔ A14–12)
FRS ↔ GND (A15 16 ↔ A14 12)
IG ↔ GND (A14–11 ↔ A14–12)
IG ↔ GND (A14 11 ↔ A14 12)
AVENSIS/CORONA SUP (RM781E)
AIR CONDITIONING
IG ON. Set temp.: Except MAX. COOL
IG ON. Set temp.: COOL
IG ON. set temp.: Except MAX. HOT
IG ON. Set temp.: HOT
IG ON. Blower motor: Operate
IG ON. Blower motor: Not operate
Light control switch: TAIL
Light control switch: OFF
IG ON. Blower motor: Operate
IG ON. Blower motor: Not operate
Always
IG ON. Air inlet selector: RECIRCULATE
IG ON. Air inlet selector: FRESH
IG ON. Air inlet selector: FRESH
IG ON. Air inlet selector: RECIRCULATE
IG ON.
IG OFF.
AIR CONDITIONER AMPLIFIER
Below 1.0 V
10 – 14 V
Below 1.0 V
10 – 14 V
Below 1.0 V
10 – 14 V
10 – 14 V
0 V
Pulse generation
10 – 14 V
1 Ω or less
Below 0.7 V
10 – 14 V
Below 0.7 V
10 – 14 V
10 – 14 V
0 V