AVENSIS/CORONA SUP (RM781E)
AUTOMATIC TRANSAXLE (A246E)
9.
(a)
(b)
F00683
10.
(a)
A
D04313
(b)
NOTICE:
When pressing down the grooved pin, if doing it at the
place other than the notch, there may be fear of damaging
the shift lever sub–assembly.
(c)
(d)
F00687
11.
Using a screwdriver and a hammer, remove the 4 collars.
F00685
–
FLOOR SHIFT ASSEMBLY (LHD)
REMOVE SHIFT LEVER SUB–ASSEMBLY
Using a screwdriver and a hammer, remove the control
shaft.
Remove the shift lever sub–assembly.
DISASSEMBLE SHIFT LEVER SUB–ASSEMBLY
Measure the distance "A" between the lower edge of the
shift lever knob sleeve and the upper edge of the shift le-
ver sub–assembly.
Using a hammer, remove the grooved pin.
Remove the detent rod and spring.
Remove the shift lever knob sleeve from the detent rod.
REMOVE COLLARS
AX–15