Toyota AVENSIS 2000 Supplement Manual page 590

Hide thumbs Also See for AVENSIS 2000:
Table of Contents

Advertisement

AVENSIS/CORONA SUP (RM781E)
AUTOMATIC TRANSAXLE (A246E)
REMOVAL
1.
2.
3.
4.
5.
6.
7.
F00497
8.
9.
F00483
10.
(a)
(b)
11.
(a)
(b)
F00705
12.
(a)
AUTOMATIC TRANSAXLE UNIT
REMOVE BATTERY
REMOVE AIR CLEANER
REMOVE GROUND CABLE
Torque: 18 N·m (185 kgf·cm, 13 ft·lbf)
REMOVE 2 UPPER SIDE TRANSAXLE MOUNTING
BOLTS FROM TRANSAXLE SIDE
Torque: 64 N·m (650 kgf·cm, 47 ft·lbf)
REMOVE UPPER SIDE STARTER MOUNTING BOLT
Torque: 39 N·m (400 kgf·cm, 29 ft·lbf)
DISCONNECT VEHICLE SPEED SENSOR CONNEC-
TOR
REMOVE LH AND RH ENGINE UNDER COVERS
REMOVE DRAIN PLUG AND DRAIN ATF
Torque: 17 N·m (175 kgf·cm, 13 ft·lbf)
REMOVE LH AND RH DRIVE SHAFTS (See page
SA–3)
DISCONNECT SOLENOID CONNECTOR AND NEU-
TRAL START SWITCH CONNECTOR
Disconnect the solenoid connector and the neutral start
switch connector.
Remove the wire harness clamps.
REMOVE SHIFT CONTROL CABLE
Remove the nut from the control shift lever.
Torque: 12 N·m (120 kgf·cm, 9 ft·lbf)
Remove the clip and disconnect the control cable.
REMOVE FRONT CENTER MEMBER
RHD:
Remove the nut and disconnect the suction hose from the
front center member.
AX–29
AX10X–01

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents