A
B
C
AVENSIS/CORONA SUP (RM781E)
MANUAL TRANSAXLE (C50, C250)
3.
(a)
D
(b)
CM0066
If the outer diameter is less than the minimum, replace the input
shaft.
(c)
If the runout exceeds the maximum, replace the input shaft.
CM0013
–
INPUT SHAFT
INSPECT INPUT SHAFT
Check the input shaft for wear or damage.
Using a micrometer, measure the outer diameter of the in-
put shaft journal surface.
Minimum outer diameter:
Part A: 24.885 mm (0.9797 in.)
Part B: 28.985 mm (1.1411 in.)
Part C: 30.985 mm (1.2199 in.)
Part D: 24.985 mm (0.9834 in.)
Using a dial indicator, check the shaft runout.
Maximum runout: 0.03 mm (0.0012 in.)
MX–27